Hioki 3332 single phase power tester
As the efficient use of energy for home and office appliances is becoming increasingly essential. The Hioki 3332 single phase power tester does the job by providing a wide range of power measurements from standby to normal usage.
The Hioki 3332 single-phase power meter is capable of evaluating 3-phase devices, such as industrial refrigerators and refrigerators, or large-scale single-phase appliances.
Both power testers offer high accuracy ± 0.2% (45 to 66Hz), direct input up to 50A, and bandwidth from 1Hz (3331 from 10Hz) to 100kHz. Building the system is made easy with these compact, lightweight and affordable tools, equipped with an external interface as a standard feature. 3331 and 3332 can be used as a measurement ingredient for a variety of purposes
- Very low effective power can be measured, for home use device standby
- Extremely sensitive measurement, used to measure the effective power of the device in standby mode:
- 1,0000 mA full-scale current, 0.1 µA resolution
- Wide measuring range, up to 50,000 One direct input
Main specifications:
Measurement lines | Single-phase 2-wires |
---|---|
Measurement items | Voltage, Current, Current peak, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency, Power integration, Current integration |
Measurement ranges | [Voltage] 15/ 30/ 60/ 150/ 300/ 600 V AC [Current] 1/ 2/ 5/ 10/ 20/ 50/ 100/ 200/ 500 mA, 1/ 2/ 5/ 10/ 20/ 50 A AC [Power] 15.000 mW to 30.000 kW (combination of voltage and current ranges) [Frequency] Auto/ 500 Hz/ 100 kHz (select voltage or current) |
Input resistance (50/60 Hz) | [Voltage] 2 MΩ, [Current] 2 mΩ or less (direct input) |
Basic accuracy | ±0.1 % rdg. ±0.1 % f.s. (45 Hz to 66 Hz) |
Display refresh rate | 5 times/s |
Frequency characteristics | 1 Hz to 100 kHz |
Integration measurement | Data update time: 5 times/s, Measurement range: 0.00000 m to ±999999 MAh/MWh, (integration time up to 10,000 hours) |
Wave peak measurement | Current I (displays max. absolute value), Effective input range: Six times the current range, or Max. 90 A peak |
D/A output | Number of channel: 1 ch, Output items: Voltage, Current, Current peak, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency, Integration |
Analog output | Voltage, Current, Power simultaneously, DC ±5 V f.s. |
Monitor output | Voltage, Current simultaneously (waveform output), 1 Vrms f.s. |
Other functions | Comparator function for 2 measurement items (Decision for Hi /In /Lo and relay output), Backup, Scaling, Average function |
Interfaces | RS-232C, GP-IB standard |
Power supply | 100 to 240 V AC, 50/60 Hz, 40 VA max. (at 100 to 120 V AC), 50 VA max. (at 200 to 240 V AC) |
Dimensions and mass | 210 mm (8.27 in) W × 100 mm (3.94 in) H × 261 mm (10.28 in) D, 2.7 kg (95.2 oz) |
Accessories | Instruction manual ×1, Power cord ×1, Connector for EXT I/O ×1 |