Testo 324 pressure gauge and leak detector
The testo 324 pressure gauge and gas leak detector allows for pressure measurements, DVGW-approved leak detection for all gas pipeline tests, tightness and maintenance checks.
The testo 324 pressure/leak detector can be used for the following applications
- Leak tightness checks on gas pipes (leak tightness check and load test according to TRGI 2008 and DVGW G 5952)
- Serviceability checks according to TRGI 2008 on gas pipes
- Pressure tests on water pipes (drinking water according to ZVSHK EN 806-4, waste water according to DIN EN 1610)
- Leak tightness checks on liquid gas pipes according to TRF 2012
- Gas pressure regulator inspections
- Pipe volume measurements
- Further applications including temperature measurements at radiators and pressure measurements at burners (die pressure, gas flow pressure…)
Temperature – NTC | |
---|---|
Measuring range | -20 to +100 °C |
Temperature – TC Type K (NiCr-Ni) | |
---|---|
Measuring range | -40 to +600 °C |
Accuracy | ±0.5 °C or ±0.5 % |
Absolute Pressure | |
---|---|
Measuring range | 600 to 1150 hPa |
Accuracy | ±3 hPa |
Overload | to 1200 hPa |
Leakage measurement | |
---|---|
Measuring range | 0 to 10 l/h |
Accuracy | ±0.2 l/h or ±5 % of mv |
Resolution | 0.1 l/h |
Pressure measurement | |
---|---|
Measuring range | 0 to 1000 hPa |
Accuracy | ±0.5 hPa or ±3 % of mv |
Pressure measurement (external probe) | |
---|---|
Measuring range | 0 to 25 bar |
Accuracy | ±0.6 % fs (0 to 10 bar) ±0.6 % fs (> 10 to 25 bar) |
General technical data | |
---|---|
Overload | 1200 hPa |
Weight | 1070 g |
Dimensions | 270 x 90 x 75 mm |
Operating temperature | +5 to +40 °C |
Protection class | IP40 acc. to EN 60529 |
Additional probe sockets | 2 Hirschmann sockets for connecting pressure and temperature probes |
Gas connections | 2 pressure connections DN 5 |
DVGW permit according to 5925 | Instrument class L up to volume = 200 litres |
Display type | Colour display, presentation of graphic curves |
Data transfer | USB, IRDA, Bluetooth® (option) |
Battery life | approx. 5 h measurement time, mains operation possible |
Storage temperature | -20 to +50 °C |
Pipe volume calculation | |
---|---|
Measuring range | max. 1200 l |
Accuracy | ±0.2 or ±5 (1 to 200 l)F |