Fluke 1623-2 GEO Earth Ground Tester
The Fluke 1623-2 GEO Earth Ground Tester are able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod.
This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall of Potential test method must be used.
With Stakeless testing, the earth ground rod does not need to be disconnected—leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil.
The Fluke 1623-2 GEO Earth Ground Tester offers expanded versatility and ease of set up. This all leads to a more effective and efficient earth ground tester that allows you to work faster and in more locations.
The Fluke 1623-2 is a unique earth ground tester that can perform all four types of earth ground measurement:
- 3- and 4-Pole Fall of Potential (using stakes)
- 4-Pole Soil Resistivity testing (using stakes)
- Selective testing (using 1 clamp and stakes)
- Stakeless testing (using 2 clamps only)
Easy to use, for each test the testers inform you which stakes or clamps need to be connected and the large rotary switch can be used even with a gloved hand.
Features
- 3 and 4 pole Fall of potential
- Earth resistance loop testing
- 4 pole soil resistivity testing
- Stakeless earth ground rod testing using 2 clamps
- IP56 rated for outdoor use
- Operating temp: 14 to 122°F (-10 to 50°C)
- Instant measurement through TURN and START one button concept
- Measuring voltage 48 VAC
- Internal memory storage up to 1500 records
Stakeless Testing:
The 1623-2 is able to measure earth ground loop resistance using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by the clamp and the current is measured using the second clamp. The 1623-2 then automatically determines the resistance of the earth ground rod.
With stakeless testing, the earth ground rod does not need to be disconnected – leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system – a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons or anywhere you don’t have access to soil.
What’s in the Box
- Test leads
- 4 earth ground stakes
- 3 cable reels with wire
- 2 clamps
- Batteries
- Manual
- Carrying case