Fluke 177 True-RMS Digital Multimeter
With its precision, reliability and ease of use, the Fluke 177 Digital Multimeter is the preferred solution for professional technicians worldwide. Independently tested for safe use in CAT IV 600 V/ CAT III 1000 V environments, the Fluke 177 is the industry standard with all the features you need to troubleshoot and repair many problems in electrical and electronic systems.
The Fluke 177 Digital Multimeter gives you True-rms voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 177 provides higher 0.09% basic accuracy, a digital display with analog bar graph and backlight.
Features:
The Fluke 177 Digital Multimeter features 0.09 percent basic DC voltage accuracy. Have a Backlight to Illuminate the Screen in Dark Workspaces. 6000 counts, updates 4 x second digital and 33 segments, updates 40 x second analog bar graph display. Automatically turns off after 2 minutes to save battery life; the timeout feature can be disabled by a power-up option. Hold: freezes the display at the push of a button; auto hold: display holds present reading until it detects the new stable input, then the meter beeps and displays new reading.
Minimum, maximum, and average reading memory; In auto range, the meter selects the range with the best resolution for the present measured value. The beeper sounds with a stretched pulse for opens or shorts as brief as 250 microseconds; The message “LEAd” appears briefly on the display when the rotary switch is moved to or from any A (Amps) position.
Turn on all LCD segments, Disable beeper, Disable sleep mode, Enable smoothing. The instrument comes with built-in probe holders for probe storage and for convenience when making measurements. Battery replacement without voiding calibration. The integrated overmolded protection provides superior impact protection for your meter. Lifetime warranty. IEC 1010 CAT IV 600V, CAT III 1000V Safety Ratings.
Fluke 177 Specifications
Voltage DC | |
Accuracy | ±(0.09% + 2) |
Maximum Resolution | 0.1 mV |
Maximum | 1000 V |
Voltage AC | |
Accuracy | ±(1.0% + 3) |
Maximum Resolution | 0.1 mV |
Maximum | 1000 V |
Current DC | |
Accuracy | ±(1.0% + 3) |
Maximum Resolution | 0.01 mA |
Maximum | 10 A |
Current AC | |
Accuracy | ±(1.5% + 3) |
Maximum Resolution | 0.01 mA |
Maximum | 10 A |
Resistance | |
Accuracy | ±(0.9% + 1) |
Maximum Resolution | 0.1 Ω |
Maximum | 50 MΩ |
Capacitance | |
Accuracy | ±(1.2% + 2) |
Maximum Resolution | 1 nF |
Maximum | 10,000 µF |
Frequency | |
Accuracy | ±(0.1% + 1) |
Maximum Resolution | 0.01 Hz |
Maximum | 100 kHz |
Environmental Specifications | |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -22 to 140°F (-30 to 60°C) |
Humidity (Without Condensation) | 0 to 90% at 32 to 95°F (0 to 35°C) 0 to 70% at 95 to 122°F (35 to 50°C) |
Safety Specifications | |
Overvoltage Category | EN 61010–1 to 1000 V CAT III EN 61010–1 to 600 V CAT IV |
Agency Approvals | UL, CSA, TÜV listed and VDE Pending |
General Specifications | |
Battery Life | Alkaline approximately 200 hours typical, without backlight |
Dimensions | 1.7 x 3.5 x 7.3″ (43 x 90 x 185 mm) |
Weight | 14.8 oz (420 g) |